Seitenansicht 0
MP3000 Door Operator
RF Kit Kit RFR1Instructions -
Page 1
RFR1
24VDC
Power Supply
6-32 x 1/4 “ Phillips
Round Head Screw
(Qty 4)
6-32 x 3/8 Standoff
(Qty 4)
RFR1 Kit instructions for installing a 433MHz Receiver in a MP3000 unit
Step 4. Connect (3) short splicing wires (provided) to the three
position terminal on the RFR1 Power Supply
Terminal 1 ----(Black wire)
Terminal 2 ----(White wire)
Terminal 3 ----(Green wire)
Use these wires
for splicing
Pull slack in wires to
this area for Tap
Connectors
Step 3. Mount power supply as
illustrated
Step 2. Note the wires that will be spliced into the 120VAC supply
Hot ------------ (Black wire)
Common ----- (White wire)
Earth Ground (Green wire)
Power supply will be mounted on stand offs over top of the
wires shown
Black
White
Green
Step 5. Use the three tap connectors (provided) to splice power
supply leads into units 120VAC power.
Splice Black to Black; White to White; and
.
Green to
Green
Step 1. Toggle circuit breaker to OFF position to terminate power
to unit before proceeding
A7872B
Step 6. Mount 433MHz Receiver to unit as shown using Velcro
strip provided
Use cable ties (provided) to secure the RF’s wiring
harness to the units existing wiring to insure RF’s wiring
will not come in contact with sprockets or chain
CAUTION
!
R
© SARGENT Manufacturing Company 2006
An ASSA ABLOY Group company
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - RF Kit Kit RFR1Instructions

MP3000 Door OperatorRF Kit Kit RFR1Instructions -Page 1RFR124VDCPower Supply6-32 x 1/4 “ PhillipsRound Head Screw(Qty 4)6-32 x 3/8 Standoff(Qty 4)RFR1

Seite 2

Step 7. Connect wiring harness of 433MHz Receiver to unit asshownStep 8. Toggle circuit breaker switch to RESET position to turnpower input to unit on

Kommentare zu diesen Handbüchern

Keine Kommentare